AutoQuiz: What are the Electrical Standards for Industrial Machinery Emergencies?

AutoQuiz is edited by Joel Don, ISA's social media community manager.

Today's automation industry quiz question comes from the ISA Certified Automation Professional certification program. ISA CAP certification provides a non-biased, third-party, objective assessment and confirmation of an automation professional's skills. The CAP exam is focused on direction, definition,AutoQuiz-electrical-standards-emergencies-NFPA design, development/application, deployment, documentation, and support of systems, software, and equipment used in control systems, manufacturing information systems, systems integration, and operational consulting. Click this link for information about the CAP program. This question is from the CAP study guide, Domain II.

According to NFPA Electrical Standards for Industrial Machinery, which of the following actions is NOT acceptable for emergency operations?

a) using a locally supplied disconnect
b) using an emergency stop to override all other functions and operations with all modes
c) using an emergency switch off initiated by a single human action
d) resetting an emergency stop circuit to initiate a restart
e) none of the above

 

The reset of an emergency stop circuit will not initiate a restart; therefore, the answer is not an acceptable emergency operation. Emergency stop to override all other functions and operations with all modes is an acceptable emergency operation, per NFPA 79 - 9.2.5.4.11. Emergency switching off initiated by a single human action is an acceptable emergency operation, per NFPA 79 - 9.2.5.4.1. Using a locally supplied disconnect is an acceptable emergency operation, per NFPA - 10.7.5.1.

The correct answer is D, resetting an emergency stop circuit to initiate a restart.

 

Joel Don
Joel Don
Joel Don is an independent content marketing, social media and public relations consultant. Prior to his work in marketing and PR, Joel served as an editor for regional newspapers and national magazines throughout the U.S. He earned a master's degree from the Medill School at Northwestern University with a focus on science, engineering and biomedical marketing communications, and a bachelor of science degree from UC San Diego.

Related Posts

What are the Biggest Mistakes You Have Seen? Part 3

The following discussion is part of an occasional series showcasing the ISA Mentor Program, authored by G...
Greg McMillan Jul 1, 2022 5:30:00 AM

How is Automation Changing Chemical Plants?

Automation is becoming a gamechanger in various industries. Decision makers need to figure out how best t...
Emily Newton Jun 28, 2022 5:30:00 AM

ISA Commemorates International Women in Engineering Day

Since 1982, women have earned almost 10 million more college degrees than men. However, despite this stat...
Steven Aliano Jun 23, 2022 5:30:00 AM