ISA Interchange

Welcome to the official blog of the International Society of Automation (ISA).

This blog covers numerous topics on industrial automation such as operations & management, continuous & batch processing, connectivity, manufacturing & machine control, and Industry 4.0.

The material and information contained on this website is for general information purposes only. ISA blog posts may be authored by ISA staff and guest authors from the automation community. Views and opinions expressed by a guest author are solely their own, and do not necessarily represent those of ISA. Posts made by guest authors have been subject to peer review.

All Posts

AutoQuiz: How to Minimize the Effect of Feed Upsets to the Top of a Distillation Column

AutoQuiz is edited by Joel Don, ISA's social media community manager.

Today's automation industry quiz question comes from the ISA Certified Automation Professional certification program. ISA CAP certification provides a non-biased, third-party, objective assessment and confirmation of an automation professional's skills. The CAP exam is focused on direction, definition, design, development/application, deployment, documentation, and support of systems, software, and equipment used in control systems, manufacturing information systems, systems integration, and operational consulting. Click this link for information about the CAP program. The following question comes from the CAP study guide, Performance Domain II, Definition: Identify customer requirements and complete high-level analysis of the best way to meet those requirements.

 

To MINIMIZE the effect of feed upsets to the top of a distillation column, the flow feed forward signal should be connected to a tray temperature controller output that then directly manipulates a(n):

a) overhead pressure controller
b) linear reflux valve
c) reflux controller
d) reboiler stream ratio controller
e) none of the above

 

A distillation tower has feed upsets that are measured and used to create a feed forward signal. A reflux flow controller remote set point becomes the feed multiplied by a reflux-to-feed ratio that the temperature controller output will correct. This is the most linear and accurate way of maintaining the material balance as long as the flow measurements are above their low range ability limit.

The correct answer is C, reflux controller.

 

Joel Don
Joel Don
Joel Don is an independent content marketing, social media and public relations consultant. Prior to his work in marketing and PR, Joel served as an editor for regional newspapers and national magazines throughout the U.S. He earned a master's degree from the Medill School at Northwestern University with a focus on science, engineering and biomedical marketing communications, and a bachelor of science degree from UC San Diego.

Related Posts

ISA Podcast Recaps the 2025 Automation Summit & Expo

The International Society of Automation (ISA) podcast, Podomation, curates and shares insightful discussi...
Kara Phelps Nov 24, 2025 7:00:00 AM

Ask the Automation Pros: What Can Be Done to Improve the Accuracy of Totalized Liquid Mass Charge?

The following discussion is part of an occasional series, “Ask the Automation Pros,” authored by Greg McM...
Greg McMillan Nov 21, 2025 10:00:00 AM

Leveraging Shop Floor Data for Improvement in Operational Technology

In the modern industrial landscape, data is not just a byproduct; it is the backbone of operational excel...
Ashraf Sainudeen Nov 14, 2025 1:00:00 PM