The material and information contained on this website is for general information purposes only. ISA blog posts may be authored by ISA staff and guest authors from the automation community. Views and opinions expressed by a guest author are solely their own, and do not necessarily represent those of ISA. Posts made by guest authors have been subject to peer review.

All Posts

AutoQuiz: How Do You Minimize the Effect of Feed Upsets to the Top of a Distillation Column?

AutoQuiz is edited by Joel Don, ISA's social media community manager.

Today's automation industry quiz question comes from the ISA Certified Automation Professional certification program.  ISA CAP certification provides a non-biased, third-party, objective assessment and confirmation of an automation professional's skills. The CAP exam is focused on minimize-effect-feed-upsets-distillation-column-oil-industrydirection, definition, design, development/application, deployment, documentation, and support of systems, software, and equipment used in control systems, manufacturing information systems, systems integration, and operational consulting. Click this link for information about the CAP program. This question is from the CAP study guide, Domain II.

To minimize the effect of feed upsets to the top of a distillation column, the flow feed forward signal should be connected to a tray temperature controller output that then directly manipulates a(n):

a) overhead pressure controller
b) linear reflux valve
c) reflux controller
d) reboiler stream ratio controller
e) none of the above

    

A distillation tower has feed upsets that can produce a feedforward signal. A reflux flow controller remote setpoint becomes the feed multiplied by a reflux-to-feed ratio that the temperature controller output will correct. This is the most linear and accurate way of maintaining the material balance as long as the flow measurements are above their low range ability limit. Changes in the pressure drop of a linear reflux valve and the valve installed characteristics and deadband will introduce errors into the feed-forward. Manipulating a pressure controller setpoint will not set up a flow ratio to maintain the material balance. A ratio controller uses a ratio of flows as its controlled variable. This creates a nonlinear loop. Also, the remote set point would be incorrect, and steam would have a slower, and generally smaller, effect than reflux flow on the top.

The correct answer is C, the reflux controller.

Joel Don
Joel Don
Joel Don is an independent content marketing, social media and public relations consultant. Prior to his work in marketing and PR, Joel served as an editor for regional newspapers and national magazines throughout the U.S. He earned a master's degree from the Medill School at Northwestern University with a focus on science, engineering and biomedical marketing communications, and a bachelor of science degree from UC San Diego.

Related Posts

Ask the Automation Pros: How to Best Migrate from Obsolete to Modern Instrumentation and Control Systems?

The following discussion is part of an occasional series, "Ask the Automation Pros," authored by Greg McM...
Greg McMillan Apr 30, 2024 7:00:00 AM

Jonas Berge on Becoming an ISA Fellow

The International Society of Automation (ISA) sat down with Jonas Berge, one of four individuals to be el...
Liz Neiman Apr 26, 2024 9:56:16 AM

Four Reasons Why Automation Is the Future of Metal Fabrication

Although automated fabrication was once a relatively niche possibility, more shop managers consider it a ...
Emily Newton Apr 24, 2024 9:40:13 AM