The material and information contained on this website is for general information purposes only. ISA blog posts may be authored by ISA staff and guest authors from the automation community. Views and opinions expressed by a guest author are solely their own, and do not necessarily represent those of ISA. Posts made by guest authors have been subject to peer review.

All Posts

AutoQuiz: How to Install Thermocouple Extension Wires

 

AutoQuiz is edited by Joel Don, ISA's social media community manager.

 

This automation industry quiz question comes from the ISA Certified Control Systems Technician (CCST) program. Certified Control System Technicians calibrate, document, troubleshoot, and repair/replace instrumentation for systems that measure and control level, temperature, pressure, flow, and other process variables. Click this link for more information about the CCST program.

 

 

When connecting a “K” type thermocouple to a control system where extension wires are required, it is important to use only properly installed “KX” extension wires because:

a) this prevents the formation of a second temperature measurement junction
b) the manufacturer’s warranty for the thermocouple would be voided if “KX” extension wire is not used
c) “KX” thermocouple extension wire comes with special connectors for making the connection
d) “KX” thermocouple extension wire is cheaper than “JX” thermocouple extension wire and reduces installation cost
e) none of the above

 

Proper installation of thermocouple extension wires also requires special terminal blocks to prevent additional junctions from being formed.

The correct answer is A; it prevents the formation of a second temperature measurement junction. A thermocouple measurement junction is formed wherever two dissimilar metals are joined. KX-type thermocouple extension wire is made of the same metals as the K-type thermocouple (chromel and alumel). When extending the thermocouple leads with an extension wire back to the control system input card, KX thermocouple extension wire must be used, and the chromel wire and the alumel wire must be joined to the wire of the same metal in the extension cable. If JX or another type of extension wire is used, another measurement junction is formed. For instance, if JX extension cable is used in the example in this problem, the point where the iron and chromel wires are joined would form another thermocouple. This will negatively affect the intended measurement signal.

Reference: Goettsche, L.D. (Editor), Maintenance of Instruments and Systems, 2nd Edition

 

About the Editor
Joel Don is the community manager for ISA and is an independent content marketing, social media and public relations consultant. Prior to his work in marketing and PR, Joel served as an editor for regional newspapers and national magazines throughout the U.S. He earned a master's degree from the Medill School at Northwestern University with a focus on science, engineering and biomedical marketing communications, and a bachelor of science degree from UC San Diego.

 

Connect with Joel
LinkedInTwitterEmail

 

 

Joel Don
Joel Don
Joel Don is an independent content marketing, social media and public relations consultant. Prior to his work in marketing and PR, Joel served as an editor for regional newspapers and national magazines throughout the U.S. He earned a master's degree from the Medill School at Northwestern University with a focus on science, engineering and biomedical marketing communications, and a bachelor of science degree from UC San Diego.

Related Posts

Checking In With Mimo, ISA's Large Language Model Trained on ISA Content

Over the summer of 2024, the International Society of Automation (ISA) announced a large language model (...
Kara Phelps Nov 15, 2024 7:00:00 AM

Ask the Automation Pros: The Use of Artificial Intelligence in Process Control

The following discussion is part of an occasional series, "Ask the Automation Pros," authored by Greg McM...
Greg McMillan Nov 12, 2024 4:30:00 PM

Protecting Electrical Terminal Blocks From Tampering

Electrical terminal blocks are a common sight in the automation world. Usually mounted on DIN rail in ind...
Anna Goncharova Nov 8, 2024 10:30:00 AM